Certificate of analysis

Lot RX-FB80-2609-01

Retest needed: detection limit too high

Not yet released: this lab report does not include heavy metals or microbiology results. The lot is held until they are reported.

The lab did not detect 7-OH or MP, but its detection limits add up to more than 1 mg/g, so this report cannot show the combined limit is met. The lot is held until it is retested with a more sensitive method.

246810121416Retention time (min) · response, √ scale · illustrative trace from lot resultsMitragynine86.4%Corynantheidine4.1%Paynantheine2.8%Speciociliatine2.3%Speciogynine1.6%7-OH window · ×100Federal threshold 1.0 mg/gND (< 0.56 mg/g)
Alkaloid trace for lot RX-FB80-2609-01, tested 2026-09-30 by Infinite Chemical Analysis Labs, San Diego. Hover or tap a peak for its value.How to read a COA
ProductHigh-Purity MIT Extract — Freebase
GradeFreebase 80
ManufacturedNot stated
Tested2026-09-30
LaboratoryInfinite Chemical Analysis Labs, San Diego (California-licensed laboratory C8-0000047-LIC)
Mitragynine86.4% w/w
Total kratom alkaloids97.2% w/w
Corynantheidine4.1% w/w
Paynantheine2.8% w/w
Speciociliatine2.3% w/w
Speciogynine1.6% w/w
7-hydroxymitragynineNot detected (< 0.56 mg/g) (limit 1 mg/g)
Mitragynine pseudoindoxylNot detected (< 0.92 mg/g) (limit 1 mg/g)
MIT : (7-OH + MP)≥ 585 : 1 (minimum 100 : 1)
Heavy metals (Pb, As, Cd, Hg)Not tested
MicrobiologyNot tested
Residual solventsPass

The laboratory report is available to approved buyers on request.

← High-Purity MIT Extract — Freebase